- Scenes can now be stored in DME Designer while Online. You can store a scene while online but the scene will keep its default name. Please go off-line to edit the scene name.
- Muteless synchronization “From DME64N/DME24N to DME Designer” is available
- The synchronization process has been improved.
In this version, synchronization from DME Designer to DME64N/24N can be done without audio interruption, but with the following exceptions:
- The 1st time (*) data is transferred after DME Designer software is launched.
- When changes to project data between DME Designer software and DME64N/DME24N is outside of the following
(for example if you make any other changes such as placing new components, changing wiring between components)
1. Parameters in components
2. AD/DA parameters for AD824/AD8HR/DME24N
3. Parameters in MY-Cards
(*)No audio interruption will occur even when the 1st transfer is made, if the project file has been saved before closing DME Designer last time.
- Added a function to use the REMOTE connector as a MIDI connector, corresponding to both RS232C and RS422.
It is set by the REMOTE parameter on the Misc page of Utility Display (Bold fonts below are added in this version).
“HA Control ”,
Control for an external head amp. (Only for RS422)
“COM (RS232C)”
“COM (RS422)”
Control via a DME communication protocol using RS232C/RS422
“MIDI (RS232C)”
“MIDI (RS422)”
Control via a MIDI command using RS232C/RS422
- Sped up the compile by approximately three times when Auto Delay Compensation is On, and approximately double when Auto Delay Compensation is Off.
- After a scene is stored, it is recalled automatically (previously it had to be recalled manually).
- Dealt with the property editing for the same type of multiple objects in Designer Window.
- Dealt with Undo and Redo shortcuts (Ctrl + Z/Ctrl + Y) on the Component Editor.