V1.25

Fixed bugs

  • Fixed a problem in which the meters of the channels other than the currently selected channel and the adjacent channels did not move when the PM5D and the DSP5D units were cascade-connected and the DSP5D was selected for the PM5D panel operation under the following conditions.
    • The same metering point was specified for the channel strip meters and for the meters at the top of the top panel.
    • The meter of a different layer was displayed on the channel strip meters and the meters at the top of the top panel.
    • A specific screen such as EQ or COMP was displayed.
  • Fixed a problem in which the GR indicator of the channel that uses no COMP/GATE function flashed instantaneously by switching the channel layers with a screen other than COMP or GATE screen displayed, when the PM5D and the DSP5D units were cascade-connected and the DSP5D was selected for the PM5D panel operation.
  • Fixed a problem in which the GR meter continued to display the maximum value on the panel or screen of the selected channel and its paired channel when the PM5D and the DSP5D units were cascade-connected and the DSP5D was selected for the PM5D panel operation under the following conditions. To fix this problem, update the DSP5D firmware as well as the PM5D firmware.
    • VERTICAL PAIR was selected for the PAIR MODE.
    • GATE and/or COMP of the selected and its paired channels were set to ON.
    • A different layer was selected for the INPUT channel strip meters and for the meters at the top of the top panel.