DME64N, DME24N
Firmware, Designer

DME-N/DME Satellite Firmware V3.09

New Features

  • The PM5D console can now communicate with the group master DME whose ID is not limited to only 2 but also allows other numbers, when remotely controlling the DME units from the PM5D (DME Control function). In this case, however, the PM5D firmware must be V2.20 or later.
  • The screen image appearing when the DME64N/24N starts up can now be replaced with a graphic file of your choice in the following way. This function allows you to display a desired startup screen-for example, one that includes your facility's name and logo.

    Preparing the graphic data
    Create the desired graphic data at a size of 160 x 48 dots in black-and-white bitmap format (extension .bmp) and save it as a file with the name "opening.bmp."

    Replacing the graphic data
    Transmit the graphic file ("opening.bmp") to the DME unit using the DME File Storage function from the DME Designer. This image will be displayed at the startup screen from the next time when the DME starts up.

    Other information
    To restore the default startup screen, create a dummy file and change the name to "blank.bmp." and storage it in the same way as above. The default startup screen will be displayed from the next time when the DME starts up.
    The file transmitted to the DME unit using the DME File Storage function will be automatically erased after completing the internal configuration. This means the file is not stored on the DME unit.
    Compatible graphic files are limited to black-and-white bitmap format at a size of 160 x 48. Other graphic files cannot be displayed.
    The "Copyright" indication at the bottom of the screen cannot be erased.
    Only the DME64N/24N is compatible with this function. The ICP1 is incompatible.

Fixed Bugs

  • Fixed a problem in which opening and closing the communication ports repeatedly could result in the ports becoming unavailable when an external controller such as AMX/Crestron remotely controlled the DME Satellite units via Ethernet.
  • Fixed a problem in which the GPI IN function would occasionally not respond to the input signal correctly when a Level parameter of Fader component or Frequency parameter of EQ component was assigned and the Min/Max value was changed on the GPI dialog box of the DME Designer.
  • Fixed a problem in which scenes could not be recalled only on the group master DME when scenes were recalled continuously from external devices, such as via MIDI signals.
  • Fixed a problem in which recalling a scene which included parameter links in a component which included a recall safe setting could occasionally require a long time for the recall operation to be completed.
  • Fixed a problem in which recalling a library on a component could occasionally require a long time for the recall operation to be completed.

TOP

DME Designer V3.0.1

New Features

  • TXn series and ACD1 are added to an external device list.

Fixed Bugs

  1. Fixed a problem in which the DME Designer would occasionally quit unexpectedly when analyzing a configuration of a specific file which required a long time to analyze.
  2. Fixed a problem in which opening and closing the GPI dialog box could result in operation freeze, depending on your particular computer.
  3. Fixed a problem in which the meters would occasionally not function correctly when operating online with DME for a long time.
  4. Fixed a problem in which a synchronization error would occur when synchronizing via the direction [DME Designer <- Device], after being previously set to the [DME Designer -> Device] direction, if the DME Designer V2 or later opened a project file including a scene created by the DME Designer V1, and the scene was copied and pasted.
  5. Fixed a problem in which WAV files could not be saved to computer by synchronizing via the direction [DME Designer <- Device], if the folder specified in [ContentsFolder] did not allow write access. In this case, WAV files are now saved in the "My Documents" folder.
  6. Fixed a problem in which the Auto Save function would mistakenly save files at one-minute intervals after once initially saving files correctly at the specified interval.
  7. Fixed a problem in which an error message would appear even when a backup operation was completed successfully if WAV files were registered in the DME.
  8. Fixed a message appearing when the firmware was updated. Updating the firmware will erase some data on the DME regardless of the firmware version. Back up all important data to your computer before updating.
  9. Fixed a message appearing when the DME64N units in different device groups were cascade-connected, informing that audio signals could be transferred, but the auto-delay compensation would not work.
  10. Fixed a problem in which selecting an editor window from the main panel [Window] menu would activate the parent window if the editor window had been opened from another editor window.
  11. Moved the menu location of external devices NHB32-C/ACU16-C/NAI48-ES which could be placed on the designer window from [External Device] -> [Processor] to [External Device] -> [Interface].
  12. Fixed a problem in which the Undo operation would become unavailable (the [Undo] command of the designer window [Edit] menu became grayed-out) when saving user modules as templates by the [Save User Module] command.
  13. Fixed a problem in which user module names would not appear correctly in the context menu if the names included an "&" character. Also fixed was a problem in which component names and user control names would not appear correctly in the [Window] menu if the names included an "&" character.
  14. Fixed a problem in which only one user module would appear in the "Parameter List" dialog box when multiple user modules had the same name (i.e., when having renamed to the same name after creating new user modules).
  15. Fixed a problem in which user module parameters that have been security engaged would not appear in the "Parameter List" dialog box.
  16. Fixed messages of the "Parameter Link Setting Dialog" dialog box appearing when copying and pasting components including parameter links. In addition, the dialog box now shows a message when the number of links is already at maximum.
  17. Fixed a problem in which component parameters which had included previously-deleted controls would be also saved when storing a library in the user control editor.
  18. Fixed a problem in which the resized knobs of SPX components would not be displayed properly in the user control editor.
  19. Fixed a problem in which double-clicking a project file would not start up the DME Designer (depending on your particular computer) if Windows XP SP2 and SP3 were applied.

DME-N/DME Satellite Firmware V3.06
SP2060 Firmware V1.22

Fixed bugs

  1. Fixed a problem in which the Wav file registered on the Wav File Manager list 001 could not be played back after the DME was restarted.
  2. Fixed a problem in which the DME would freeze when the Room Combiner component parameters were changed from an external device (remote control, MIDI, or GPI).
  3. The response speed has been improved for assigned parameters to be changed once the DME receives a trigger signal via the GPI IN connector.

TOP

DME-N/DME Satellite Firmware V3.04
SP2060 Firmware V1.22

New Features

The internal head amps of the DME64N/24N (with an AVY16-ES card) can now be controlled directly through the slot via EtherSound without using the REMOTE terminal. To use this function, from the AVS-ESMonitor application set "Serial Port Mode" to "Internal Slot Port <-> EtherSound" and "Baud Rate" to "38400." Please note that on the DME64N you can only use slot 3 and 4.

Fixed bugs

  1. When Utility or Network settings are changed from DME Designer, the device display now shows a message indicating that the settings are being stored as well (for the DME Satellite the [SIGNAL] indicators light consecutively in a clockwise direction).Do not turn the power off while the settings are being stored; doing so may damage the data.
  2. Fixed a problem that when the DME64N/24N was used with an MY8-AE96(S) inserted to the slot and a certain channel input signal was unlocked or failed in synchronization, noise was generated to another channel input signal.

TOP

DME Satellite Firmware V3.03

Fixed Bugs

Fixed a problem in which the sound was sometimes intermittent during increases in the internal processing load on the DME8i-ES/DME8o-ES/DME4io-ES.

TOP

DME-N Firmware V3.02

Fixed Bugs

A problem in which synchronization process with the DME64N/24N occasionally stops has been fixed.

TOP

DME Designer V3.0.0
DME64N/DME24N/ICP1 Firmware V3.01
DME Satellite Firmware V3.01

New Features

  1. click here to see the main features of V3.
  2. Windows Vista is now supported.
  3. The appropriate DME-N Network Driver version can be now installed automatically with the DME Designer application.
  4. The following connections to the Slave DME units are now possible when a DME Satellite unit is assigned as the Device Group Master:
    1. USB/Ethernet connection to the computer (DME Designer).
    2. Cascade connection to control from the PM5D console (DME64N only).
  5. It is now possible to individually set each user control to determine whether it will open automatically when the project file is opened.
  6. In accordance with the above change, the Startup User Control item has been removed from the Security dialog box.
  7. The display format of the parameter values displayed in the Remote Control Setup List and Parameter List dialog box can now be switched between the internal settings and the values displayed in the editor windows.
  8. It is now possible to set the DME unit so that the internally stored event log is not erased.
  9. Remote control from AMX, Crestron, and similar controllers is now possible via Ethernet connection only for DME Satellite units
  10. It is now possible to set a "clear" background color for text, box, and ellipse objects.
  11. Component and parameter links can now be copied when DME objects, components, and user modules are copied/pasted or duplicated.
  12. Parameter links are now saved when User Module data is saved/exported.
  13. [Line] and [Scene Recall Button] tools have been added to the User Module Editor and User Control Editor design modes.
  14. More options are available for customizing the controls in the User Module Editor and User Control Editor:
  15. A property dialog box has been added for sliders, allowing customization of direction, scale, color, size, and other parameters.
  16. Level meter size can be customized.
  17. A property dialog box has been added for slider level meters, allowing customization of direction and size.
  18. Knob color and knob background color can be customized.
  19. Text background color can be customized.
  20. A property dialog box has been added for indicators, allowing customization of color and size.

More features

Fixed bugs

  1. The "Device Group" parameter name shown on the device display panel has been fixed to "Master/Slave."
  2. The processing speed when Matrix Mixer component parameters are changed has been improved.
  3. A problem in which the current scene number cannot be sometimes obtained by the "GCS command" of the DME Remote Control Protocol has been fixed.
  4. A problem (in copying/pasting an object in the Designer window) in which a copied object larger than the sheet size could be pasted has been fixed; only objects smaller than the sheet size can be pasted.

DME Designer V2.1.0

New Features

  1. Windows Vista is now supported.
  2. The appropriate DME-N Network Driver version can be now installed automatically with the DME Designer application.

TOP

SP2060 Firmware V1.20

New Features

  1. A password can be set for the User Lock function.
  2. The output port names of components for each output channel can be shown on the device display panel.

Fixed bugs

  1. The "Device Group" parameter name shown on the device display panel has been fixed to "Master/Slave."
  2. A problem in which the current library names for output 5/6 channels are linked in the "2x2way+2xAuxL" configuration has been fixed.

TOP

DME64N/DME24N Firmware V2.02
DME Designer V2.0.1

Fixed Bugs

  1. Fixed a problem that when the PM5D (with an inserted MY16-C or MY16CII) tried to control the DME via the CobraNet network, the connection was sometimes dropped just after the communication started.
  2. DME version 2.02 now has the same capacity for the DME File Storage function as version 1.24 or earlier versions (more space than version 2.00 or 2.01). However, if you have updated the DME from version 2.00 or 2.01 to version 2.02, please follow the steps below to apply the update.
    1. Click the [On-line] button in the lower right corner of the DME Designer main panel. The "Synchronization" dialog box appears.
    2. Click the [Go On-line] button while holding down the [Ctrl] key on your keyboard to open the "Sync Direction" dialog box.
    3. Select [DME Designer -> Device] and click the [OK] button. Synchronization will start.
    4. The synchronization completes when "Mount Start <Success>" appears in the Message field of the "Synchronization" dialog box.
  3. Fixed a problem that the DMEs sometimes responded unexpectedly twice to a remote control command SPR or SVL sent to the DMEs from an external device.
  4. Fixed a problem that the User Defined Button and the Global Link did not function properly when the device group was configured with multiple factory-set DMEs and synchronized from the DME Designer application.

SP2060 Firmware V1.12

New Features

Fixed a problem that audio sometimes stopped when the DIGITAL INPUT was selected as the input and the SP2060 was rebooted.

TOP

DME64N/DME24N Firmware V2.01
DME Designer V2.0.1

New Features

  1. The DME File Storage function is now active only in offline status.
  2. A file saved using the DME File Storage function will not be deleted when the internal memory is initialized by "Initialize DME".

SP2060 Firmware V1.11

New Features

It can be now controlled via DME Designer V2.0.1.

DME64N/DME24N Firmware V2.00
DME Designer V2.0.0

New Features

  1. Support added for DME8i-C/DME8o-C/DME4io-C, SP2060 units and MY16-CII.
  2. A Feed back Suppressor component has been added (DME64N, DME24N).
  3. The Speaker Processor component PEQ "Q" parameter now goes to "63".
  4. A new concept "Device Group" has been added between "Zone" and "Configuration".
  5. A zone can have multiple device groups, to each of which the master device can be arranged.
  6. Scene Link function has been added to allow simultaneous control of multiple devices in different device groups.
  7. A host address other than "2" can also be assigned for group masters. This makes it possible to have multiple device groups at a single network address.
  8. Component Link function has been added to allow simultaneous linking of all component parameters.
  9. The Last Memory Resume function has been added to recover parameters that were set at the last power-off.
  10. The Recovery Update function has been added to allow recovery from program corruption.
  11. Firmware and component data can now be updated simultaneously.
  12. A Utility window has been added to allow editing of device utility settings from the DME Designer.
  13. Processing speed has been increased in the User Control Editor and User Module.
  14. Controlling the DME from the PM5D via CobraNet is now faster. Use the version 1.21 of the PM5D firmware or later.
  15. A [Level Meter Enable] command that displays or hides the meter values has been added to the contextual menu. Hiding the meters can result in increased communication speed in some cases.
  16. Holding the spacebar on the keyboard changes the cursor to a hand tool.
  17. When [Prohibit Diagonal Connections] in the [Tools] menu is active it is possible to select 2 diagonal points and those points will automatically be connected by a combination of horizontal and vertical wires.
  18. A [Display Order] function that allows the order of the controllers to be changed as required has been added to the User Control Editor and User Module Editor.
  19. MY card settings has been excluded from scene data.
  20. The DME File Storage function is active only in offline status.
  21. A file saved using the DME File Storage function will not be deleted when the internal memory is initialized by "Initialize DME".

TOP

DME-N Firmware V1.24

Please use DME-N Firmware V1.24 with DME Designer V1.2.1.

Fixed Bugs

  1. After multiple DME64N/24Ns have been disconnected due to network failure while they were in use, the connection between these multiple DME64N/24Ns was not restored even after the network failure was fixed.
  2. While multiple DME64N/24Ns were in use, the DME64N/24N was sometimes rendered inoperable showing a message, “Communication to Zone1 lost” if too many meter displays were shown using DME Designer.

TOP

DME-N Firmware V1.23

Fixed Bugs

  1. Fixed a problem that Remote control will not be enabled by switching on the power after saving the “COM (232C)” setting.
  2. Fixed a problem that data for a channel other than 1 cannot be obtained when one channel is obtained with the Get Meter command of the Remote function.
  3. Fixed a problem that meter data is not produced sometimes using the Get Meter (GMT) command of Remote control even though the channel is receiving audio.

TOP

DME-N Firmware V1.22

Fixed Bugs

A bug regarding RECALL SAFE is fixed.
Fixed a problem that synchronisation fails to complete when a Remote Control Setup List parameter 65 or greater is assigned.

TOP

DME-N Firmware V1.21

New Features

  1. Communications protocol to easily control DME-N from an external device such as AMX and Crestron is now supported. The "DME-N Remote Control Protocol Specifications" will be soon available on this site.
  2. Speaker Processor and Source Selector components have been added.
  3. External Devices can be double-clicked to open a file saved by other applications.
  4. A Generic “MY-Others” setting has been provided to accommodate third-party MY cards. The following cards are supported by this function.
    • "AVY16-ES" EtherSound card made by AuviTran
    • "AVIOM16/o-Y1" A-Net card made by AVIOM
    • "MY16MADI64" MADI card made by AudioService
  5. Synchronization is possible when no MY card or a different MY card is installed in the DME-N unit (a confirmation dialog will appear).
  6. A message appears to warn when synchronization will cause muting.
  7. The on-line indicator appears as a button which can be used to switch between on-line and off-line.
  8. The following operations can be performed while on line:
    • Scene name changes.
    • Fade ON/OFF and Fade Mode changes.
    • Fade time changes.
    • Parameter link setting changes.
  9. A MIDI Setup minimize function has been added.
  10. Scene edits cause the EDIT indicator to appear.
  11. Parameter values, scene recall, GPI output, Wave file playback, and head amp gain can be set via the User Defined Buttons.
  12. Files can be saved in the DME-N unit.
  13. An automatic hot-spot connection function has been added.
  14. Limiter, Slot In, Cascade In, and Cascade Out components have been added.
  15. Event Log events can be output via GPI.
  16. Different zones can be specified for use by different users.
  17. User Control can be created for individual users as well as security levels.
  18. Shortcuts can be freely set as required. And the following operations can be carried out via the shortcut keys.
    • Navigator
    • Activate Navigator
    • Activate Toolkit
    • Activate Design Window
    • Select Left Port and Start Wiring
    • Select Right Port and Start Wiring
    • Wire Auto Single to Right
    • Wire Auto Multi to Right
    • Wire Auto Single to Left
    • Wire Auto Multi to Left
    • Delete Wire
  19. Head amp gain and MY-Card can be set via GPI, MIDI, User defined Button, DAW Control.
  20. An option to allow mouse-over zooming of the edit box has been added.
  21. Snap copy is possible.
  22. Snap can be retained until the application is quit or another file is opened.
  23. DME object ports can be freely specified.
  24. Port colors can be independently specified for each port type.
  25. Port display has been added to External Device, Picture, DME, and ICP1 objects.
  26. Addition External Device types have been provided.
  27. A [Close All Editor Windows] button has been added to the Window menu.
  28. A [Close All Editor Windows] button has been added to the contextual menu.
  29. Wave files can be saved as DME data files, and are included in import/export operations.
  30. Wave files can be saved in the Wav file library.
  31. Picture objects can be double-clicked to open a specified editor.
  32. Text objects can be double-clicked to open a specified editor.
  33. Exceptions can be specified for Event Scheduler execution day/time.
  34. Event Scheduler execution times can be specified in 1-second increments.
  35. It is possible to specify whether listed events will be executed by the Event Scheduler.
  36. The order of same-time events can be changed in the Event Scheduler.
  37. Files related to user modules (user module files, library files, user module editor files) can be combined and exported/imported as a single file.
  38. User module port labels can be edited.
  39. Graphics can be placed to represent user modules.
  40. A [Back] button that allows switching between related parent and child windows has been added.
  41. An option to automatically close the dialog after synchronization has been added.
  42. A progress bar has been added to the Synchronization dialog.
  43. An auto file save function (Auto Save, post synchronization) has been added.
  44. A scroll bar appears when the size of the component editor window is reduced.
  45. The size and position of the component editor window are memorized.
  46. Default wire thicknesses and types can be independently specified for each port type.
  47. When drawing wires the keyboard cursor keys can be used to move the mouse cursor, and the <Enter> key can be used to create nodes.
  48. When drawing wires <Shift> key plus <->> key and <Shift> key plus <<-> key combinations can be used to automatically connect horizontally-aligned hot spots.
  49. The Legend field automatically resizes to accommodate project names and titles of different lengths.
  50. Security status is displayed in the user module editor status bar.
  51. Multiple controllers can be selected by clicking while holding the <Ctrl> key when the editor is in the design mode.
  52. [Picture], [Text], [Box], [Ellipse], and [Frame] have been added to the tool palette of the user module editor and user control editor design mode.
  53. Controller properties can be accessed by double-clicking controllers in the user module editor or user control editor design mode.
  54. Picture and Text objects can be clicked to open a specified editor in the user module editor or user control editor.
  55. The User Module Editor and User Control Editor offer a greater range of customization options for color, size. etc., of the placed controls.
  56. [Select All] and [Clear All] buttons have been added to the Scene Manager Recall Safe dialog.
  57. Scene parameters related to User Defined Button, Program Change, GPI In and GPI Out can be set via the Scene Manager.
  58. External head amp parameters will be recognized by the DME-N unit when either the DME-N or the external head amp (AD824, AD8HR) are turned on. Execute a scene recall to send DME-N settings an external head amp.
  59. The default value for HA Gain of AD8HR and DME24N is changed to +10dBu.
  60. Compilation of configurations with loop connections is possible when Auto Delay Compensation is On.
  61. The Delay algorithm has been revised.
    • LEVEL and MUTE are effective when Delay is Off for each channel.
    • The name of the overall Delay [On] parameter has been changed to [Bypass].
  62. The default setting of bus send level for Delay Matrix and Matrix Mixer components has been changed from -Inf to 0.0 dB.
  63. DME Designer owner’s manual is now separate from the DME Designer installer, and cannot be accessed from the DME Designer menus.
  64. The Component Lock function dialog is separate from the Parameter List dialog.
  65. It is now possible to clear an Event Log recorded in DME-N itself while offline. A DME Log Clear button that was previously in the Log Setup Dialog is moved to the Get Log dialog.
  66. The FILE menu names in the main panel window are changed as shown below.
    • Import DME->Import DME Configuration
    • Export DME->Export DME Configuration

Fixed Bugs

  1. When two channels were paired from the PM5D Editor while the PM5D was being previewed, the PM5D Editor did not show them as a pair.
  2. Fixed a problem that external head amplifiers (AD824, AD8HR) are set at the wrong time during scene recall.
  3. Fixed a problem that values shown in a zone master and slave do not correspond with each other when assigning a parameter which is globally linked to a User Defined button.
  4. Fixed a problem that the communication between DME-N and DME Designer is sometimes interrupted while showing multiple DME-N meters on DME Designer.
  5. Fixed a problem that the Peak Hold settings for meter components are not properly transmitted during synchronization from DME Designer to DME-N.
  6. Fixed a problem that a Wav file cannot be loaded by synchronizing it from DME-N to DME Designer if the Wav file name has 26 letters, which is the maximum.
  7. Fixed a problem that LPF and HPF frequencies do not follow when multiple DME-N crossover frequencies are operated by Global Parameter Link.
  8. Fixed a problem that Event Log does not specify a DME-N log that is currently shown when multiple DME-N's are connected.
  9. Fixed a problem that an Effect name will not be stored correctly by storing data in the SPX Library while online.
  10. The Slot number display for DME24N is changed to Slot1 from Slot4 in the Word Clock dialog.
  11. Fixed a problem that Library Recall for a component is disabled if a check mark for "Edit" is removed on the Security display.
  12. Fixed a problem that the edit display for an unintended event will open by double-clicking on a list in the Event Scheduler dialog when the list is sorted by some other way than No.
  13. It is now not possible to assign the same parameter for the same component within one DME-N to be edited by Multiple User Defined buttons.
  14. Fixed a problem that a label for an MY card Slot Output on a Component and Component Editor title bar did not correspond.
  15. Fixed a problem that the Show Signal Delay button icon remained illuminated, in the event that the sample rate was changed with Show Signal Delay enabled.
  16. Fixed a problem that Cascade Settings were not transferred during synchronization, after settings had been changed offline, after the first synchronization.
  17. Fixed a problem that caused incorrect levels to be recalled when interrupting an existing fade between two scenes with a different scene.

TOP

DME Firmware V1.16

Fixed Bugs

  1. Fixed a problem that MY8-AE96S Sampling Rate Converter only works on channels CH1/CH2.
  2. Fixed a problem that when a slot with MY16-C installed is selected as the master clock, DME24N/DME64N works at 48kHz even if the clock frequency of MY16-C is set at 96kHz by the dip switch.

TOP

DME-N Firmware V1.15
DME Designer V1.1.5

Fixed Bugs

  1. Fixed a problem that synchronization fails from the second time when two or more AD8HR or AD824 are connected.
  2. Fixed a problem that "-28dB" is set for Gain of AD824 if it is attempted to set "-38dB" using DME Designer.
  3. Fixed a problem that recalling a scene does not always recall the parameters for AD8HR or AD824 properly
  4. Fixed a problem that a De-Esser component parameter cannot be operated by User Define Button, MIDI, GPI or DAW controller.
  5. Fixed a problem that an event occurs at an unintended time, depending on the settings of the Event Scheduler.
  6. Fixed a problem that local link settings disappear after synchronising from DME to Designer when multiple DME-Ns are connected.
  7. Fixed a problem that a parameter link setting which is not stored in a scene disappears by saving a project file.
  8. Fixed a problem that when two or more AD8HRs are connected, the setting of +48V Master for other units than the first is not displayed properly on DME Designer.
  9. Fixed a problem that the parameter link window is not displayed properly by importing a DME export file that contains a parameter link.

TOP

DME Firmware V1.14
DME Designer V1.1.4

New Features

  1. Scenes can now be stored in DME Designer while Online. You can store a scene while online but the scene will keep its default name. Please go off-line to edit the scene name.
  2. Muteless synchronization “From DME64N/DME24N to DME Designer” is available
  3. The synchronization process has been improved.
    In this version, synchronization from DME Designer to DME64N/24N can be done without audio interruption, but with the following exceptions:
    • The 1st time (*) data is transferred after DME Designer software is launched.
    • When changes to project data between DME Designer software and DME64N/DME24N is outside of the following
      (for example if you make any other changes such as placing new components, changing wiring between components)
      1. Parameters in components
      2. AD/DA parameters for AD824/AD8HR/DME24N
      3. Parameters in MY-Cards

    (*)No audio interruption will occur even when the 1st transfer is made, if the project file has been saved before closing DME Designer last time.

  4. Added a function to use the REMOTE connector as a MIDI connector, corresponding to both RS232C and RS422.
    It is set by the REMOTE parameter on the Misc page of Utility Display (Bold fonts below are added in this version).

    “HA Control ”,
    Control for an external head amp. (Only for RS422)

    “COM (RS232C)”
    “COM (RS422)”
    Control via a DME communication protocol using RS232C/RS422

    “MIDI (RS232C)”
    “MIDI (RS422)”

    Control via a MIDI command using RS232C/RS422
  5. Sped up the compile by approximately three times when Auto Delay Compensation is On, and approximately double when Auto Delay Compensation is Off.
  6. After a scene is stored, it is recalled automatically (previously it had to be recalled manually).
  7. Dealt with the property editing for the same type of multiple objects in Designer Window.
  8. Dealt with Undo and Redo shortcuts (Ctrl + Z/Ctrl + Y) on the Component Editor.

Fixed bugs

  1. Dealt with a problem that “0” is displayed as the delay value if ‘Show Signal Delay’ is selected and 64 x 64 or 64 x32 Matrix Mixer is being used.
  2. Dealt with a problem that Snaps have different contents if the user repeatedly switches the edited snaps rapidly while Online.
  3. Fixed a bug that the text on a dialog screen is not shown correctly when ‘large font’ is selected in Windows (OS) Display Preferences.
  4. Fixed a bug that Navigator and Resource Meter protrude from a display area and cannot be moved if users operate on a small display area such as a laptop after changing from a multi-display or high resolution external monitor.
  5. Fixed a bug that a project file (*.daf) created with V1.0 cannot be opened with V1.10 if a Parameter link is assigned to it.
  6. Changed the process that DME Designer used to become offline automatically if it had not communicated with DME for more than 30 seconds for any reasons. Now it stays online and shows a notification message box.
    * However, if users change it to offline, it does not recover automatically.
    * The condition above is not kept in an event log.
  7. Fixed a bug that DME Designer can not be synchronized unless the PC is restarted when a communication error of DME Network Driver occurs. It is now possible to synchronize without restarting the PC when such an error occurs. ”
  8. Fixed a bug that an inappropriate parameter value is set for GPI IN input voltage when users control a parameter through GPI IN from an external controller.
    * Note:
    An appropriate value is set only with a B-Curve controller of 10KΩ.
    Use a B-Curve controller of 10KΩ.
  9. Fixed a bug that DME does not recover unless it is restarted if users turn off AD8HR while they are editing AD8HR on the HA Utility page.
  10. Fixed a bug that the +48V of the internal head amps of DME24N are not set correctly when power is switched on.
  11. Fixed a bug that when multiple dynamics components (Comp, Auto Mixer, Crossover Processor, etc.) are placed within the same configuration, editing the parameter of one component may actually change the parameter of one of the other components.
  12. Fixed a bug that if a GPI IN channel is assigned to Scene Increment/Decrement in the [Tools]-[GPI] setting screen, the settings of higher numbered GPI IN channels are not saved. Fixed a bug that if a GPI OUT channel is assigned to GPI Lock, the settings of higher numbered GPI OUT channels are not saved.
  13. Fixed a bug that DME Designer does not synchronize or analyze if it is installed to a folder that contains multibyte characters (Japanese, etc.) (E.g.: a desktop, etc.).
  14. Fixed a bug that when users try to store a legend as a default setting, the input value is not saved as a default setting if it includes multibyte characters. Also fixed a bug that when users try to store a sheet setting as a default, it is not saved as the default setting if it includes multibyte characters.
  15. Fixed a bug that a gain reduction ratio was working at 1:20.1 even though the Ratio of the component is set at 1:∞. The following components are affected: Compressor, CompanderH, CompanderS, Expander, CrossoverProcessor, CrossoverProcessor2, De-Esser
  16. Fixed a bug that an error sometimes occurred when synchronising again from DME Designer to DME to transfer a Wav file after it was interrupted once.
  17. Fixed a bug that a registered parameter became unavailable if the security of a User Module is made to be available after a parameter within the User Module is registered in GPI, MIDI, User Defined Button, DAW Control or Event Scheduler.
  18. Modified the procedure so that a Component Lock can now be set on even if Security is set on in the ‘Save User Module’ screen.
  19. Fixed a bug that parameters such as Slot setting properties could not be initialized properly if DME is added again with the Undo operation after canceling the placement of multiple DME64N/DME24N in the Zone Design Window.