LS9
Firmware

  • Use the Editor with the supported firmware listed in the following table.

LS9 Compatibility

  • Files saved using later Editor or console versions cannot be loaded into earlier versions.
  • Please note that some types of USB flash memories cannot be used for firmware updates, or cannot be accessed from the LS9 at all.

Current Version Info

V1.15

Fixed Bugs

  • (LS9-32 only) Fixed a problem in which the latency could differ between from INPUT channels 1-32 and from INPUT channels 33-64 when signals were sent from the INPUT channels to the MIX buses.
  • (LS9-16 only) Fixed a problem in which the latency could differ between from INPUT channels 1-32 and from ST IN channels 1-4 when signals were sent from the input channels to the STEREO bus or MONO bus.
  • Fixed a problem in which an "E" (Edited) mark would not appear when (after scene recall) editing the HPF ON or HPF Frequency parameter of an external head amp device which was added to scene memories in firmware V1.14.

How to update the firmware

Before performing any firmware upgrade it is good practice to back-up console data to a USB memory device.

  1. Copy the following file to root directory of your USB memory.
    LS9Px_xx.PGM (x_xx shows the version number.)
  2. Insert your USB memory and power on.
  3. LS9 detects the file and show the following message.
    "Start Loading? CANCEL[DEC]/OK[INC]"
  4. Then press [INC] key to start updating the firmware.
  5. Wait until completing the update. LS9 automatically restarts and becomes ready to use.

Performance Limits and Specifications

They are the same as V1.10.

TOP