<!--- ▽▼▽▼▽▼▽▼▽▼▽▼▽▼ Section Importanat Notice ▽▼▽▼▽▼▽▼▽▼▽▼▽▼ -----> <ul class="normal"> <li>The [PREVIEW] key and Help functions will be available in future updates.</li> <li>Integrated function with Nuendo Live works only with the CL CONSOLE that is set to ID#1.</li> <li>When multiple PCs running DVS are connected, the CL CONSOLE will only integrate with Nuendo Live on the PC which has the lowest RACK No. on the CL CONSOLE.</li> </ul> <!--- ▲△▲△▲△▲△▲△▲△▲△ Section Importanat Notice ▲△▲△▲△▲△▲△▲△▲△ -----> <br /> <!--- ▽▼▽▼▽▼▽▼▽▼▽▼▽▼ Section Compatibility ▽▼▽▼▽▼▽▼▽▼▽▼▽▼ -----> <h3 class="headingD01">CL/Rio Compatibility</h3> <p>Please make sure to use appropriate version of CL Editor which is compatible with your CL firmware in reference to the following compatibility chart. Using an unsupported Editor/firmware combination may result in unexpected behavior.</p> <div class="tableA01"> <table class="specTable" style="font-size: 0.9em;"> <tbody> <tr> <th rowspan="2">CL Editor</th> <th colspan="3">CL Firmware</th> <th colspan="2">Rio Firmware</th> </tr> <tr> <th>Main</th> <th>SUB</th> <th>DANTE</th> <th>MAIN</th> <th>DANTE</th> </tr> <tr> <td rowspan="2">1.1.0</td> <td>1.12</td> <td rowspan="2">1.12</td> <td rowspan="2">3.6.4.7 - 3.4.2.1 - 1.0.8</td> <td rowspan="2">1.11</td> <td rowspan="2">3.6.4.7 - 3.4.2.1 - 1.0.8</td> </tr> <tr> <td>1.11</td> </tr> <tr> <th class="col" rowspan="3">1.0.0</th> <th class="col">1.04</th> <th class="col">1.04</th> <th class="col" rowspan="3">3.6.3.0 - 3.4.1.0 - 1.0.4</th> <th class="col" rowspan="3">1.02</th> <th class="col" rowspan="3">3.6.3.0 - 3.4.1.0 - 1.0.4</th> </tr> <tr> <th class="col">1.03</th> <th class="col" rowspan="2">1.02</th> </tr> <tr> <th class="col">1.02</th> </tr> </tbody> </table> </div> <!--- ▲△▲△▲△▲△▲△▲△▲△ Section Compatibility ▲△▲△▲△▲△▲△▲△▲△ ----->

V1.04 to V1.11

Improvement

  • Now supports Nuendo Live.
  • Added the GPI functions.
  • Several User Keys can be stored inside the console.
  • Changed the configurations of the DANTE SETUP window.
  • A pop-up massage appears when an I/O rack is newly recognized or removed in the Dante audio network.
  • The maximum of the number of units which can be used simultaneously is as follows:
    - Up to four CL units and up to thirty-two I/O rack units in a Dante audio network.
    - Up to eight I/O rack units which can HA remote in one CL unit.
    - Up to twenty-four I/O rack and Dante device units which can patch to one CL unit.

Fixed Bugs

  • Solved a problem in which the panel controls might occasionally freeze.
  • Solved a problem in which the Gain Compensation parameter settings were changed when a scene memory was recalled.
  • Solved a problem in which the CL series device may not have recognized Rio if the CL series was started before Rio.
  • Solved a problem in which when Dante-MY16-AUD was installed in a slot, it may have been unlocked while the Error LED on Dante-MY16-AUD lit in orange for at least 45 seconds or audio may not have been streamed.
  • Solved a problem in which if Dante-MY16-AUD was set as Slave to External Word Clock, the Sync LED may not have lit in green when the device was turned on.
  • Solved a problem in which when Dante devices (such as Rio) were not connected to the Dante connector of a CL series device, the CL was muted and audio signals were not output.
  • Solved a problem in an environment with two or more CL series devices, in which the following malfunctions may have occurred with the I/O RACK OUTPUT PATCH pop-up window.
    - A port patched to a different CL series device could not be canceled, but a message would appear, indicating that the port could be canceled.
    - When a file was loaded, patching could not be reproduced, even though the WITH DANTE SETUP AND I/O RACK button was on when the file was loaded.
  • Solved a problem in which when devices with the Dante -MY16-AUD were rebooted, recalling patching of CL series devices and Dante-MY16-AUD may have taken several minutes.
  • Solved a problem in which it may not have been possible to store or recall Dante Input Patch settings to or from the library, even if the Dante Controller was used for patching the Dante Virtual Soundcard (DVS) to the CL series device.
  • Improved the performance in which when a preset file was loaded and patch settings were changed while a CL series device and Rio were connected by a Dante audio network, the changes to the patch settings may not have been completed.
  • Improved the performance in which when the word clock or audio bit rate were changed with a CL series device and Rio connected by a Dante audio network, Rio may have been muted and audio may not have been outputted.

Known issue

  • If the Dante Virtual Soundcard (DVS) is patched to the CL series device using the Dante Controller, the patching may not be recalled correctly when the CL series device is restarted. Patch the DVS again.
  • In an environment with two or more CL series devices, the following malfunctions may have occurred with the I/O RACK OUTPUT PATCH pop-up window.
    A port patched to a different CL series device could not be canceled, but a message would appear, indicating that the port could be canceled.