DME Series Firmware V3.59  (Previous version)

Important Notice

  • The hardware specification for DME Firmware V3.5x or earlier differs from the one for Firmware V3.8x or later (including V4.0). Therefore firmware V3.5x or earlier cannot be upgraded to V3.81 or later. Also, firmware V3.81 or later cannot be downgraded to V3.5x or earlier. (This does not apply to the SP2060 or ICP1.) If you need to upgrade your DME from V3.5x or earlier to V3.81 or later (including V4.0), please contact your Yamaha dealer.
  • Save an up-to-date DME project file (*.daf). Don't update unless an up-to-date ".daf" file has already been saved on your computer. Without the ".daf" file, you will not be able to restore DME operation.

DME Designer/Firmware compatibility

DME Designer Version Firmware Version
  DME-N, ICP1 DME Satellite SP2060
3.8.0 3.86, 3.85, 3.84, 3.83, 3.82, 3.81*, 3.60, 3.59, 3.58, 3.57, 3.56, 3.55, 3.52, 3.51, 3.11, 3.10, 3.09, 3.06, 3.04, 3.02, 3.01 3.86, 3.85, 3.84, 3.83, 3.82, 3.81*, 3.60, 3.59, 3.58, 3.57, 3.56, 3.55, 3.52, 3.51, 3.11, 3.10, 3.09, 3.06, 3.04, 3.03, 3.01 1.32, 1.31, 1.30, 1.24, 1.23, 1.22, 1.21
3.5.1, 3.0.2, 3.0.1, 3.0.0 3.60, 3.59, 3.58, 3.57, 3.56, 3.55, 3.52, 3.51, 3.11, 3.10, 3.09, 3.06, 3.04, 3.02, 3.01 3.60, 3.59, 3.58, 3.57, 3.56, 3.55, 3.52, 3.51, 3.11, 3.10, 3.09, 3.06, 3.04, 3.03, 3.01 1.32, 1.31, 1.30, 1.24, 1.23, 1.22, 1.21

If the Program Ducker component is used, both DME firmware and DME Designer versions must be V3.5x or greater.

* Firmware version 3.81 is not available for download.

Main Revisions and Enhancements

Fixed Bugs

  • Fixed a bug where parameters assigned to be controlled via GPI could only be varied over a limited input voltage range when GPI Port values were set as follows in the GPI dialog window:
[Function] [Parameter] [Min]/[Max]
Parameter Value Edit A frequency parameter Any setting other than the defaults

Improvement

  • The detection accuracy of the backup battery voltage was improved.

Precautions

  • If the IP address of the DME device is changed after the device has been synchronized with DME Designer, it will be necessary to re-transfer the configuration data by performing a “Full Resync” operation to ensure proper operation of GPI control, MIDI control, Remote control, and DME Designer meter display functions.
    “Full Resync” can be initiated by clicking the [Go On-line] button (found in the Synchronization window of DME Designer) while holding down the [Ctrl] key.