  • Please make sure to use the appropriate versions of NUAGE system components which are compatible with each other, referring to the following compatibility charts. Using an unsupported component combination may result in malfunction.
  • After you update the Nuage I/O firmware by using NUAGE Workgroup Manager, be sure to manually turn on Nuage I/O again.
  • We found a problem in which the Dante settings might not be properly initialized when the firmware is updated to V1.15/V1.16, which results in data inconsistency. This might occur only when the Dante Latency was set to 0.25ms or 0.5ms. Therefore, after updating the firmware to V1.15/V1.16 it is recommended to briefly change the Latency to 1.0ms on the Dante Controller, then restore the original setting again. This will avoid the possible data inconsistency.

NUAGE System Compatibility

Windows

TOOLS for NUAGE

OS
Nuendo Cubase / Cubase Pro NUAGE FADER / MASTER Firmware NUAGE I/O Firmware (16D/16A/8A8D) DANTE ACCELERATOR
MAIN MAIN DANTE Firmware Driver
1.7.1
Windows 7 SP1 / 8.1 / 10 (64-bit)
7.0.35
6.5.40(*1) 6.0.7 (*2)(*1)
8.5.0
8.0.35 7.5.40(*1)
1.06 1.17
1.16
1.15
3.8.0.24 - 3.5.1.8 - 1.2.2 2.5.0 2.0.3
2.0.2
1.7.0
Windows 7 SP1 / 8 / 8.1 (64-bit)
7.0.20 
6.5.40 6.0.7 (*2)
8.0.20
7.5.40
2.0.2
1.6.0
Windows 7 SP1 / 8 /8.1 (64-bit)
6.5.30
6.0.7 (*2)
8.0.0
7.5.30
1.05 1.14
1.13
1.12
3.7.1.10 - 3.4.9.3 - 1.2.1 2.0.0 2.0.1
1.5.0
Windows 7 SP1 / 8 / 8.1 (32-bit/64-bit)
6.5.20
6.0.7 (*2)
7.0.4 or later
1.2.0
Windows 7 SP1 /8 / 8.1 (32-bit/64-bit)
6.0.6 - 6.0.7 1.04
1.1.0
Windows 7 SP1 / 8 /8.1 (32-bit/64-bit)
6.0.4 - 6.0.5 1.03 1.11
1.09
3.6.4.20 - 3.4.3.8 - 1.1.3 1.0.1
1.0.0
1.0.0
1.0.0
Windows 7 SP1 / 8 / 8.1 (32-bit/64-bit)
6.0.2 - 6.0.3 7.0.2 or later 1.03
1.02

*1 Nuendo 6.0.7, Nuendo 6.5.40 and Cubase 7.5.40 do not support Windows 10,.
*2 With Nuendo 6.0.7, only some additional features of V1.5.0 or later are available.

Macintosh

TOOLS for NUAGE

OS
Nuendo Cubase / Cubase Pro NUAGE FADER / MASTER Firmware NUAGE I/O Firmware (16D/16A/8A8D) DANTE ACCELERATOR
MAIN MAIN DANTE Firmware Driver
1.7.1
OS X 10.9.x/10.10.x/10.11.x
7.0.35  
6.5.40(*1) 
6.0.7 (*2)(*3)
8.5.0 (*6), 8.0.35  
7.5.40(*1)
1.06 1.17
1.16
1.15
3.8.0.24 - 3.5.1.8 - 1.2.2 2.5.0
2.5.1
1.7.0
OS X 10.8.x/10.9.x/10.10.x
7.0.20 (*4)
6.5.40, 6.0.7 (*2)(*3)
8.0.20 (*4)
7.5.40
1.6.0
OS X 10.8.x/10.9.x/10.10.x 
6.5.30-6.5.40
6.0.7 (*2)(*3)
8.0.0-8.0.5 (*4)
7.5.30-7.5.40
1.05 1.14
1.13
1.12
3.7.1.10 - 3.4.9.3 - 1.2.1
1.5.0
OS X 10.7.5/10.8.x/10.9.x
6.5.20 (*5)
6.0.7 (*3)
7.0.4 or later
1.2.0
OS X 10.7.5/10.8.x/10.9.x 
6.0.6 or later 1.04 2.5.0(*7)
2.0.0 2.0.0
1.1.0
OS X 10.7.5/10.8.x/10.9.x
6.0.4 or later 1.03 1.11
1.09
3.6.4.20 - 3.4.3.8 - 1.1.3 1.0.1 1.0.1
1.0.0(*8) 1.0.0
1.0.0
OS X 10.7.5/10.8.x/10.9.x
6.0.2 - 6.0.3 7.0.2 or later 1.03
1.02
1.0.1(*8) 1.0.1
1.0.0(*8) 1.0.0

(PULL UP / PULL DOWN function is not available in Mac OS X 10.8.)
*1 Nuendo 6.5.40 and Cubase 7.5.40 do not support Mac OS X 10.11.x.
*2 Nuendo 6.0.7 does not support Mac OS X 10.10.x, 10.11.x.
*3 With Nuendo 6.0.7, only some additional features of V1.5.0 or later are available.
*4 Cubase Pro 8 and Nuendo 7 do not support Mac OS X 10.8.x.
*5 Nuendo 6.5.x does not support Mac OS X 10.7.x.
*6 Cubase 8.5.0 does not support Mac OS X 10.9.x.
*7 Support only for Mac Pro (Late 2013) / Nuendo 6.0.7.
*8 VST System Link function is not available.

Main Revisions and Enhancements

Fixed Bugs

  • Solved a problem in which the Nuage I/O 16A or 8A8D would not retain Input and Output Trim values adjusted on the NUAGE Workgroup Manager across a power cycle.

Known Issues

  • If multiple Dante devices and one or more network switches are turned ON simultaneously in a system that uses redundant Dante connections, NUAGE I/O units connected as Dante slave devices will sometimes synchronize to their own internal clock, preventing synchronization with other Dante devices and causing intermittent noise. Turn the NUAGE I/O unit that is causing the problem OFF and then ON again.

former version information.

V1.16

Fixed Bugs
  • Solved a problem in which the Nuage I/O 16A or 8A8D would not retain Input and Output Trim values adjusted on the NUAGE Workgroup Manager across a power cycle.

V1.15

Improvement
  • Dante [SYNC] indicator (orange) flashes when communication error occurs on the Dante Redundant Network.
    Error on a primary network:

    Error on a secondary network:

Fixed Bugs

  • Solved some minor problems.

V1.14

Fixed Bugs
  • Solved a problem in which synchronization with the Dante network was unlocked and the audio was muted for several seconds depending on your system.
  • Solved some other minor problems.

V1.13

Fixed Bugs
  • Solved a problem in which audio was sometimes cut off when the cable of the [PRIMARY] connector was disconnected and then reconnected while Nuage I/O was being used in a redundancy network.
  • Solved some other minor problems.

V1.12

Fixed Bugs
  • Solved a problem in which an instantaneously noise would occur when, after turning on the power of Nuage I/O, the “Active” indications in the Workgroup would come on for the first time.
  • Solved some other minor problems.

V1.11

Fixed Bugs
  • Solved a problem in which Nuage I/O (Nio) would no longer clock correctly if the word clock source is re-connected to the BNC or AES/EBU on the Nuage I/O, after the unit receives a stable clock. Also solved a problem in which (in the above situation) the sample rate LED on the front panel would not flash even though the unit was not clocking properly.
  • Solved a problem in which sync loss may occur among samples between different channels within a Nuage series device or between different Nuage series devices.
Notice
  • Changing the sample rate of Dante Accelerator from Dante Controller sets the same sample rate for Nuendo but not for Nuage I/O(Nio). Please change the sample rate from Nuendo for the Nuage system
  • In order to use the direct monitoring of Nuage I/O, surround processor, and the system link function with SyncStation, please make sure to patch Dante Accelerator and Nuage I/O to follow the ID order from the first Nuage I/O, starting from 1-16, 17-32, then 33-48, and so on.