Print This Page

Nuage I/O Firmware V1.12 (Previous version)

Important Notice

  • Please make sure to use the appropriate versions of NUAGE system components which are compatible with each other
  • After you update the Nuage I/O firmware by using NUAGE Workgroup Manager, be sure to manually turn on Nuage I/O again.

NUAGE System Compatibility

Win : Windows 7 SP1 (32-bit/64-bit), Windows 8 (32-bit/64-bit), Windows 8.1 (32-bit/64-bit)

TOOLS for NUAGE Nuendo NUAGE FADER / MASTER Firmware NUAGE I/O Firmware (16D/16A/8A8D) DANTE ACCELERATOR
MAIN MAIN DANTE Firmware Driver
1.5.0 6.5.20
6.0.7
1.05 1.13
1.12
3.7.1.10 - 3.4.9.3 - 1.2.1 2.0.0 2.0.1
1.2.0 6.0.6 - 6.0.7 1.04
1.1.0 6.0.4 - 6.0.5 1.03 1.11
1.09
3.6.4.20 - 3.4.3.8 - 1.1.3 1.0.1
1.0.0
1.0.0
1.0.0 6.0.2 - 6.0.3 1.03
1.02

Mac OS X 10.7.5/ 10.8.x/ 10.9.x

TOOLS for NUAGE Nuendo NUAGE FADER / MASTER Firmware NUAGE I/O Firmware (16D/16A/8A8D) DANTE ACCELERATOR
MAIN MAIN DANTE Firmware Driver
1.5.0 6.5.20 (*1)
6.0.7 (*2)
1.05 1.13
1.12
3.7.1.10 - 3.4.9.3 - 1.2.1 2.5.0
2.5.1
1.2.0 6.0.6 - 6.0.7 1.04 2.5.0(*3)
2.0.0 2.0.0
1.1.0 6.0.4 -6.0.5 1.03 1.11
1.09
3.6.4.20 - 3.4.3.8 - 1.1.3 1.0.1 1.0.1
1.0.0(*4) 1.0.0
1.0.0 6.0.2 - 6.0.3 1.03
1.02
1.0.1(*4) 1.0.1
1.0.0(*4) 1.0.0

*1 Nuendo 6.5.20 does not support OS 10.7.x.
*2 With Nuendo 6.0.7, only some additional features of V1.5.0 are available.
*3 Support only for Mac Pro (Late 2013) / Nuendo 6.0.7.
*4 VST System Link function is not available.

Main Revisions and Enhancements

Main Revisions and Enhancements

  • Improved the data processing capacity of the Nuage I/O.

Fixed Bugs

  • Solved a problem in which an instantaneously noise would occur when, after turning on the power of Nuage I/O, the “Active” indications in the Workgroup would come on for the first time.
  • Solved some other minor problems.

former version information.

V1.1.2

Fixed Bugs
  • Solved a problem in which an instantaneously noise would occur when, after turning on the power of Nuage I/O, the “Active” indications in the Workgroup would come on for the first time.
  • Solved some other minor problems.

V1.1.1

Fixed Bugs
  • Solved a problem in which Nuage I/O (Nio) would no longer clock correctly if the word clock source is re-connected to the BNC or AES/EBU on the Nuage I/O, after the unit receives a stable clock. Also solved a problem in which (in the above situation) the sample rate LED on the front panel would not flash even though the unit was not clocking properly.
  • Solved a problem in which sync loss may occur among samples between different channels within a Nuage series device or between different Nuage series devices.
  • Solved a problem in which the Input Trim/Output Trim functions of the Nuage I/O 16A or 8A8D, which was adjusted by using NUAGE Workgroup Manager, would not be changed correctly.
Notice
  • Changing the sample rate of Dante Accelerator from Dante Controller sets the same sample rate for Nuendo but not for Nuage I/O(Nio). Please change the sample rate from Nuendo for the Nuage system
  • In order to use the direct monitoring of Nuage I/O, surround processor, and the system link function with SyncStation, please make sure to patch Dante Accelerator and Nuage I/O to follow the ID order from the first Nuage I/O, starting from 1-16, 17-32, then 33-48, and so on.

Important Notice(May 27, 2014)

Windows installer of Dante Firmware Update Manager included in the firmware zip file does not work due to expiration of the Authenticode certificate. Therefore you cannot install Dante Firmware Update Manager into Windows PC. The newly released Dante Firmware Update Manager v1.4.7.1 has fixed this issue. Please use it when you install it going forward. (This installer is compatible with Windows 7 or Windows 8 only.) Please note that you can use Mac OS installer included in the firmware zip file as it did not have this issue.

 Dante Firmware Update Manager for Win

License agreement and software

Nuage I/O Firmware V1.12 (Previous version)

Return to Top