Print This Page

PM5D Firmware V1.21

Important Notice

  • Make sure to unplug the cable connected to the rear-panel HA REMOTE connector during the update operations. Especially on the PM5D-RH, this may cause the internal head amps to be uncontrollable. If this happens, follow the procedures described in the upgrade guide.
  • Use the Editor software only with a supported firmware version.

PM5D Editor/Firmware Compatibility (Win)

PM5D Editor Studio Manager V2 Host PM5D Firmware
2.1.3 2.1.7 1.21, 1.20
2.1.2 1.17
2.1.1 2.1.5 1.16, 1.15, 1.14, 1.13
2.1.0 2.1.1 1.12, 1.11, 1.10

PM5D Editor/Firmware Compatibility (Mac/Power PC)

PM5D Editor Studio Manager V2 Host PM5D Firmware
2.1.3 2.1.8 1.21, 1.20
2.1.2 1.17
2.1.1 2.1.5 1.16, 1.15, 1.14, 1.13
2.1.0 2.1.1 1.12, 1.11, 1.10
  • PM5D user data is compatible with later firmware versions, but not with lower firmware versions. Cross-platform compatibility is provided for setup data which is directly saved to a compact flash memory via the PM5D, or saved as a ".PM5" file using the Editor application.

Fixed Bug

  • When an MY16-AE card or MY16-TD card was inserted into PM5D, noise could have very occasionally appeared on input channels 9-16.
  • When a set of MY16MADI64 cards were inserted into PM5D, these cards were wrongly recognized as MY8-AE cards. (These cards should be recognized as MY16-AT cards). Therefore, only signals from the first 8 channels of each card could be used, rather than all 16.