Print This Page

Rio1608-D Firmware V1.50 (Previous version)

Important Notice

  • With V1.60 firmware, we found that CL consoles may partially lose HA gain control of R series units after being powered on for a long period of time.
    We have released the new firmware V1.61 in which the serious problem was fixed, and strongly recommend to update your CL/R series units with V1.61.
  • Please do not use EEE function(*1) of Ethernet switches in a Dante network.
    It has been reported that using some Ethernet switches whose EEE function is enabled can cause audio dropouts or noise in a Dante network.
    This is because the EEE function has a bad influence on the clock synchronization of Dante making real-time communication. Please avoid the EEE function as stated below:
    1) For "Managed" switches, disable the EEE function. (You can enable/disable EEE function by application software etc.)
    2) For "Unmanaged" switches, do not use Ethernet switches that support the EEE function. (Because you cannot disable EEE function.)
    *1: EEE (Energy Efficient Ethernet) function is the technology that will allow for less power consumption during periods of low network traffic.
  • You need to update the Dante-MY16-AUD firmware to V3.3.9 or later before using the Dante-MY16-AUD with the CL series firmware V1.51.

CL/QL/R/Tio Series Editor/Firmware Compatibility

Please make sure to use appropriate version of CL Editor or QL Editor which is compatible with your console firmware in reference to the following compatibility chart. Using an unsupported Editor/firmware combination may result in unexpected behavior.
The Firmware Set is a set of main (and sub) firmware of the device and the Dante firmware. The version of Firmware Set is the same as the version of the main firmware. Refer to the release note of each firmware about the details of the Firmware Set.

CL Series QL Series R Series Tio1608-D
Rio/Ri/Ro RMio64-D RSio64-D
Editor Firmware Set Editor Firmware Set Firmware Set Firmware Set Firmware Set Firmware Set
4.1.0 4.10 4.1.0 4.10 4.10 3.11 4.10 1.01
4.0.1, 4.0.0 4.04, 4.02, 4.01, 4.00 4.0.1, 4.0.0 4.04, 4.02, 4.01, 4.00 3.11 3.11, 3.10 3.10,1.00 1.00
3.1.0 3.11, 3.10 3.1.0 3.11, 3.10 3.11, 3.10, 3.00 3.11, 3.10 3.10, 1.00
3.0.0 3.02, 3.01, 3.00 3.0.0 3.02, 3.01, 3.00 3.11, 3.10, 3.00 3.10, 3.00 -
2.0.4 2.04 1.0.8 1.08 3.11, 3.10, 3.00, 2.00 -
2.0.0 2.03 1.0.3 1.07
1.7.0 1.70 1.0.2 1.02 1.70
1.0.1 1.01
1.5.1 1.61 - - 1.61
1.5.1, 1.5.0 1.51 1.51, 1.50
1.1.4 1.15 1.15
1.14 1.14
1.1.0 1.12 1.11
1.11
1.0.0 1.04 1.02
1.03
1.02

R Series Firmware Set

Rio3224-D/Rio1608-D/Ri8-D/Ro8-D

Firmware Set Main Dante
4.10 4.10 3.10.0.19 - 4.0.3.1 - 1.3.2
3.11 3.11 3.8.0.24 - 3.5.1.8 - 1.2.2
3.10 3.10
3.00 3.00
2.00 2.01 3.7.1.10 - 3.4.9.3 - 1.2.1
1.70 1.70
1.61 1.61 3.6.4.20-3.4.3.8-1.1.0
1.51, 1.50 1.51, 1.50
1.15 1.15
1.14 1.14 3.6.4.7 - 3.4.2.1 - 1.0.8
1.11 1.11
1.02 1.02 3.6.3.0 - 3.4.1.0 - 1.0.4

RMio64-D

Firmware Set Main Dante
3.11 3.11 3.8.0.24 - 3.5.1.8 - 1.2.2
3.10 3.10
3.00 3.00
1.00 1.00 3.7.1.10 - 3.4.9.3 - 1.2.1

RSio64-D

Firmware Set Main Dante
4.10 4.10 3.10.0.19 - 4.0.3.1 - 1.3.2
3.10 3.10 3.8.0.24 - 3.5.1.8 - 1.2.2
1.00 1.00

Main Revisions and Enhancements

Improvement

  • Improved with specific network switching in which, when the Rio is turned on, the Rio links at 100Mbps.

Fixed bug

  • Solved a problem in which, when the Rio1608-D with AD8HR mode engaged was mounted on the EXTERNAL HA page of the CL series screen, the +48V Master icons would be shown for four virtual units, instead of the correct two.

Known issue

  • If the Dante Virtual Soundcard (DVS) is patched to the CL series device using Dante Controller, the patching may not be recalled correctly when the CL series device is restarted. Patch DVS again. In addition, when using a version of DVS for Windows that is older than v3.2.0, the patch after CH41 cannot be performed from CL series consoles.
    *If you update the device from the V1.15 firmware, update the MAIN firmware only. To update the MAIN firmware, perform operations of only the section “Updating the Rio firmware” in the “Rio3224-D/Rio1608-D Firmware Update Guide.”
    If you update the device from other than the V1.15 firmware, update the Rio device by following the steps in the “Rio3224-D/Rio1608-D Firmware Update Guide.”

Notice

  • When setting up latency on the Dante Controller, and there is a discrepancy in latency with the transmit device or the receive device, the largest (slowest) latency setting becomes effective.

License agreement and software