Print This Page

XP7000, XP5000, XP3500, XP2500, XP1000

Please select 3 products to compare.

  • XP7000
  • XP5000
  • XP3500
  • XP2500
  • XP1000
100V modelsXP7000XP5000XP3500XP2500XP1000
Dynamic power; 1kHz 20ms nonclip2ohms1400W x 21050W x 21000W x 2800W x 2250W x 2
4ohms; Bridge2800W2100W1000W1600W500W
Output power; 1kHz4ohms1100W x 2750W x 2590W x 2390W x 2120W x 2
8ohms750W x 2525W x 2390W x 2275W x 2110W x 2
8ohms; Bridge2200W1500W1180W780W240W
Output power; 20Hz-20kHz4ohms930W x 2700W x 2450W x 2300W x 2100W x 2
8ohms700W x 2500W x 2350W x 2250W x 2100W x 2
8ohms; Bridge1860W1400W900W600W200W
70V line625W x 2 / 8ohms----
100V line--625W, Bridge / 16ohms--
120V modelsXP7000XP5000XP3500XP2500XP1000
Dynamic power; 1kHz 20ms nonclip2ohms1600W x 21300W x 21000W x 2650W x 2250W x 2
4ohms; Bridge3200W2600W2000W1300W500W
Output power; 1kHz4ohms1100W x 2750W x 2590W x 2390W x 2165W x 2
8ohms750W x 2525W x 2390W x 2275W x 2135W x 2
8ohms; Bridge2200W1500W1180W780W330W
Output power; 20Hz-20kHz4ohms950W x 2700W x 2450W x 2300W x 2125W x 2
8ohms700W x 2500W x 2350W x 2250W x 2110W x 2
8ohms; Bridge1900W1400W900W600W250W
70V line625W x 2 / 8ohms----
100V line--625W, Bridge / 16ohms--
230V modelsXP7000XP5000XP3500XP2500XP1000
Dynamic power; 1kHz 20ms nonclip2ohms1600W x 21300W x 2925W x 2650W x 2250W x 2
4ohms; Bridge3200W2600W1850W1300W500W
Output power; 1kHz4ohms1100W x 2750W x 2590W x 2390W x 2155W x 2
8ohms750W x 2525W x 2390W x 2275W x 2125W x 2
8ohms; Bridge2200W1500W1180W780W310W
Output power; 20Hz-20kHz4ohms950W x 2700W x 2435W x 2295W x 2115W x 2
8ohms690W x 2500W x 2350W x 2250W x 2100W x 2
8ohms; Bridge1900W1400W870W590W230W
70V line625W x 2 / 8ohms----
100V line--625W, Bridge / 16ohms--
240V modelsXP7000XP5000XP3500XP2500XP1000
Dynamic power; 1kHz 20ms nonclip2ohms1600W x 21300W x 21000W x 2650W x 2250W x 2
4ohms; Bridge3200W2600W2000W1300W500W
Output power; 1kHz4ohms1100W x 2750W x 2590W x 2390W x 2155W x 2
8ohms750W x 2525W x 2390W x 2275W x 2120W x 2
8ohms; Bridge2200W1500W1180W780W310W
Output power; 20Hz-20kHz4ohms950W x 2700W x 2450W x 2300W x 2110W x 2
8ohms700W x 2500W x 2350W x 2250W x 2100W x 2
8ohms; Bridge1900W1400W900W600W220W
70V line625W x 2 / 8ohms----
100V line--625W, Bridge / 16ohms--
General specificationsXP7000XP5000XP3500XP2500XP1000
Total harmonic distortionLess than 0.1% (20Hz-20kHz; Halfpower), RL=4ohmsLess than 0.1% (20Hz-20kHz; Halfpower), RL=4ohmsLess than 0.1% (20Hz-20kHz; Halfpower), RL=4ohmsLess than 0.1% (20Hz-20kHz; Halfpower), RL=4ohmsLess than 0.1% (20Hz-20kHz; Halfpower), RL=4ohms
Intermodulation distortionLess than 0.1% (60Hz:7kHz=4:1; Halfpower)Less than 0.1% (60Hz:7kHz=4:1; Halfpower)Less than 0.1% (60Hz:7kHz=4:1; Halfpower)Less than 0.1% (60Hz:7kHz=4:1; Halfpower)Less than 0.1% (60Hz:7kHz=4:1; Halfpower)
Frequency response+0dB, -1.0dB (RL=8ohms, 20Hz - 20kHz)+0dB, -1.0dB (RL=8ohms, 20Hz - 20kHz)+0dB, -1.0dB (RL=8ohms, 20Hz - 20kHz)+0dB, -1.0dB (RL=8ohms, 20Hz - 20kHz)+0dB, -1.0dB (RL=8ohms, 20Hz - 20kHz)
S/N ratio104dB103dB102dB100dB96dB
Power band width10Hz-40kHz10Hz-40kHz10Hz-40kHz10Hz-40kHz10Hz-40kHz
CrosstalkLess than -70dBLess than -70dBLess than -70dBLess than -70dBLess than -70dB
Damping factorMore than 350More than 350More than 200More than 200More than 200
Voltage gain32dB/26dB / 35.7dB (+4dBu)32dB/26dB / 34.2dB (+4dBu)32dB/26dB / 32.7dB (+4dBu)32dB/26dB / 31.2dB (+4dBu)32dB/26dB / 27.2dB (+4dBu)
Input sensitivity+7.7dBu (32dB), +13.7dBu (26dB), +4dBu+6.2dBu (32dB), +12.2dBu (26dB), +4dBu+4.7dBu (32dB), +10.7dBu, (26dB), +4dBu+3.2dBu (32dB), +9.2dBu, (26dB), +4dB-0.8dBu (32dB)、+5.2dB (26dB), +4dB
Maximum input voltage+22dBu+22dBu+22dBu+22dBu+22dBu
I/O ConnectorsLine input / output ports2x XLR-3-31 type, 2x Euroblock connector2x XLR-3-31 type, 2x Euroblock connector2x XLR-3-31 type, 2x Euroblock connector2x XLR-3-31 type, 2x Euroblock connector2x XLR-3-31 type, 2x Euroblock connector
Speaker output ports2x speakON, 2x 5-way binding post2x speakON, 2x 5-way binding post2x speakON, 2x 5-way binding post2x speakON, 2x 5-way binding post2x speakON, 2x 5-way binding post
Control portsD-sub 15pinD-sub 15pinD-sub 15pinD-sub 15pinD-sub 15pin
ProcessorsHPF (20Hz/55Hz/OFF, 12dB/Oct)HPF (20Hz/55Hz/OFF, 12dB/Oct)HPF (20Hz/55Hz/OFF, 12dB/Oct)HPF (20Hz/55Hz/OFF, 12dB/Oct)HPF (20Hz/55Hz/OFF, 12dB/Oct)
Protection circuitLoad protectionPower switch on/off mute, DC-fault: Amplifier shuts down automatically. (Operation not restored automatically), Clip limiting (THD ≥ 0.5%)Power switch on/off mute, DC-fault: Amplifier shuts down automatically.(Operation not restored automatically), Clip limiting (THD ≥ 0.5%)Power switch on/off mute, DC-fault: Amplifier shuts down automatically.(Outputrelay off/returns automatically), Clip limiting (THD ≥ 0.5%)Power switch on/off mute, DC-fault: Amplifier shuts down automatically.(Output Relay off), Clip limiting (THD ≥ 0.5%)Power switch on/off mute, DC-fault: Amplifier shuts down automatically.(Output Relay off), Clip limiting (THD ≥ 0.5%)
Amplifier protectionThermal (Mute the output; heatsink temp ≥ 90°C; Operation not restored automatically), VI limiter (Limit the output, RL ≤ 1ohm)Thermal (Mute the output; heatsink temp ≥ 90°C; Operation not restored automatically), VI limiter (Limit the output, RL ≤ 1ohm)Thermal (Mute the output; heatsink temp ≥ 90°C; Operation not restored automatically), VI limiter (Limit the output, RL ≤ 1ohm)Thermal (Mute the output; heatsink temp ≥ 90°C; Operation not restored automatically), VI limiter (Limit the output, RL ≤ 1ohm)Thermal (Mute the output; heatsink temp ≥ 90°C; Operation not restored automatically), VI limiter (Limit the output, RL ≤ 1ohm)
Power supply protectionThermal (Amplifier shuts down automatically; heatsink temp ≥ 100°C)Thermal (Amplifier shuts down automatically; heatsink temp ≥ 100°C)Thermal (Amplifier shuts down automatically; transfomer temp ≥ 130°C; Restored automatically)Thermal (Amplifier shuts down automatically; transfomer temp ≥ 130°C; Restored automatically)Thermal (Amplifier shuts down automatically; transfomer temp ≥ 130°C; Restored automatically)
Amplifier classEEEngineEEEngineEEEngineEEEngineEEEngine
Cooling2x Variable-speed fan2x Variable-speed fan1x Variable-speed fan1x Variable-speed fan1x Variable-speed fan
Power requirementsDepend on area of purchase; 100V, 120V, 230V or 240V; 50/60HzDepend on area of purchase; 100V, 120V, 230V or 240V; 50/60HzDepend on area of purchase; 100V, 120V, 230V or 240V; 50/60HzDepend on area of purchase; 100V, 120V, 230V or 240V; 50/60HzDepend on area of purchase; 100V, 120V, 230V or 240V; 50/60Hz
Power consumptionMusic source equivalent650W500W450W320W100V: 150W, 120V/230V/240V: 170W
Idling35W35W30W25W20W
Stand-by5W5W5W5W5W
DimensionsW480mm; 18-7/8in480mm; 18-7/8in480mm; 18-7/8in480mm; 18-7/8in480mm; 18-7/8in
H88mm; 3-7/16in (2U)88mm; 3-7/16in (2U)88mm; 3-7/16in (2U)88mm; 3-7/16in (2U)88mm; 3-7/16in (2U)
D456mm; 17-15/16in456mm; 17-15/16in456mm; 17-15/16in456mm; 17-15/16in456mm; 17-15/16in
Net weight14.0kg; 30.9lbs14.0kg; 30.9lbs15kg; 33.1lbs14kg; 30.9lbs12kg; 26.5lbs
AccessoriesOwner’s manual, Security cover (with a hex wrench)Owner’s manual, Security cover (with a hex wrench)Owner’s manual, Security cover (with a hex wrench)Owner’s manual, Security cover (with a hex wrench)Owner’s manual, Security cover (with a hex wrench)

0 dBu=0.775 Vrms, Half Power=1/2 Output Power (3 dB below rated power)

Return to Top

Installation Case

Trendsetting Italian club chooses Installation Series speakers

Installation Case

Built in 1884, Northampton’s Royal Theatre was designed by the renowned Victorian theatre architect C J Phipps, who also designed such prestigious venues as the Theatre Royal Bath, Theatre Royal Glasgow and Edinburgh’s Lyceum.